How to get started to use RM as programming of repeaters, both peers and master on a IPSC or Capacity plus systems.
1. Add IP system settings
Open action(Green wheel)>Manage>IP system settings
Add new as Link Establishment Repeater
Add system Alias
Master IP address(Ip to reach your master repeater)
Port(Port of your master repeater)
Add authentication key if used.
Click OK.
2. Enter Radio view, Press the radio icon top right corner
Add Master repeater by clicking on the + icon
Add Master repeater serial
Radio ID (Radio ID shown in the general settings of the repeater)
CAI = 12
Radio Alias
Click OK.
3. Right click the repeater line arrow, and from the drop down, select „select ip
system settings“
Select the one from the list that you created in step 1.
4. Select the schedule job and read, generate configuration and apply to radio
select IP programming and click OK.
5. Open RM device programmer
Check settings, confirm that IP programming is selected and click ok.
6. RM device programmer should show connection to the master at top and then
reading task of the repeater.
7. When successfully you have read the master, continue by adding all PEER
repeaters by repeating step 2 – 4.